RFC Client

Here you can configure the RFC Client. If the reports created by the ixi-UMS Kernel shall be sent to another ixi-UMS Connector, the RFC Client must be disabled.

 

You need information about your SAP-connection, that you can transmit messages and status messages.

There are two Connection Types A and B supported. Depending on your choice, you must configure different information:

 

RFC_Client_A_klein

Connection Type A:

 

Application Server: Here you must configure the same server as the RFC Destination from your SAP R/3 system.

 

System Number: It is defined by set up the RFC Destination.

 

The Client and User Data is defined by SAP and must be entered here. The required user type is "CPIC/Service" .

An RFC user is required to receive messages (including status messages). In each client in which messages are to be received, an RFC user must be created.

For information about setting up the SAP system, see How To: Configuration SAP System

 

If you enable the RFC trace, the trace files (rfc*_*.trc) are created to the installation folder of your Connector.

 

RFC_Client_B_klein

Connection Type B:

 

When set to type B, it connects to the SAP R/3 system's message server and determines the application server at run-time, what is used for load balancing.

Settings for type B:

 

The Message Server is a hostname or IP address (e.g. hs0311)

 

For R/3 system, fill in the name of the system (e.g. BIN)

 

You can optionally put in account data used by the RFC Client.

 

After having filled out all the fields, you can initiate a connection test by pressing the "Test Connection" button.

 