Depending on the PBX, some settings have to be made. The example values entered in the configuration are the default setting in combination with a Siemens Hicom 150 / HiPath 3000.

 

[GLOBAL]

Tracelevel=0

The tracelevel for the MWI-module is set here. This value is 0 by default and should only be changed upon advice of %Firma% GmbH.

0 = no trace

1 to 250 trace with more or less details; recommended 0 or 200

           e.g. Tracelevel=200

           Default: 0



Compatmode=0

This value determines in which form the ixi-UMS Kernel processes the MWI messages. Basically, the option "Compatmode=0" should be selected. In this way, the MWI messages from the messaging system can easily be set with 1 or 0.

Note: The Compatmode=1 is only used in special configurations

; Compatmode 1 = compatbility/emulation with/of Infotext/"Associated Services"

;                set infotext with 7568<Dest><InfoNum>

;                clear infotext with 7668<Dest><InfoNum>

;            0 = MWI mode

;                set MWI with 1<Dest>

;                clear MWI with 0<Dest>

 

MakeCtrlUser=2

Here it is determined what the MWI-module does with the job if NO ISDN Sender-ID is deposited in the jobfile.

1 = No changes, send job

2 = No changes, do not send job - default setting

3 = Enter default ISDN Sender-ID and send job

4 = Enter default value; if no default number is deposited, do not send job

5 = The default ISDN Sender-ID is ALWAYS entered and the job is sent

6 = ALWAYS enter default value; if no default number is deposited, do not send job

 

 

PBX:

Recommended Settings:

Hicom150 / HiPath 3000

Hicom 300 / HiPath 4000

Alcatel 4400,

OmniPCX Enterprise

 

MakeCtrlUser = 2

MakeCtrlUser = 4

MakeCtrlUser = 4 or 6 (the D-Channel Protocol ABC-F has to be set at the PBX)

 

 

DefaultCtrlUser

Depending on the PBX, a default sender number can or must be deposited. This number overrides existing sender numbers in the Alert jobfile, if applicable, and then is valid for every user. See also MakeCtrlUser.

The UMS recipient number or the MWI sender number desposited at the user is sent to the telephone as sender number by default.

PBX:

With the connection to a Siemens HiPath 4000, the "Service Access Number" must be entered here.

 

[CAPI]

CtrlNum=1

Here the wanted Controller needed for the setting of MWI messages is entered. All the MWI signalings are transmitted via this Controller. It is not possible to state more than one Controller.

 