General VoIP (XCAPI)

Wird die Telefonanlage über ein VoIP Connecting Modul angebunden, sind standardmäßig außer in der Konfiguration der Telefonanlage und der XCAPI keinerlei Konfigurationen erforderlich.

[GLOBAL]

CtrlNum

MUST

The controller required for setting MWI messages is entered here. All MWI messages are sent via this controller. It is not possible to specify multiple controllers. Default = 1

MakeCtrlUser=1

OPTIONAL

Here you define which number the MWI module uses as the "Controlling User Number" and the behavior if no "Controlling User Number" is available.

If no number is specified in the job:

1 = Do not change anything, send job

2 = Do not change anything, do not send job - default setting

3 = Enter "DefaultCtrlUser" and send job

4 = Enter "DefaultCtrlUser"; if no "DefaultCtrlUser" is stored, do not send the job

 

Regardless of whether a number is specified in the job or not:

5 = The "DefaultCtrlUser" is always entered and the job is sent

6 = Always enter the "DefaultCtrlUser"; if no "DefaultCtrlUser" is stored, do not send the job

DefaultCtrlUser

OPTIONAL

Depending on the PBX, a default sender number can or must be deposited. This number overrides existing sender numbers in the Alert jobfile, if applicable, and then is valid for every user. See also MakeCtrlUser.

The UMS recipient number or the MWI sender number desposited at the user is sent to the telephone as sender number by default.

 

Telefonanlage

Bemerkung

empfohlende Einstellungen

HiPath 4000

 

Telephone system connected via SIP

A lamp is switched and/or text is output.

MakeCtrlUser = 6

Under "DefaultCtrlUser" the so-called ServiceAccessNumber must be entered.z.B:

DefaultCtrlUser=200000

 

Version ProCall_Enterprise_7.2