Advanced Settings

Node numbers
If your PBX system is using node numbers you can enter these numbers semicolon seperated. These node numbers are removed from numbers presented by the pbx.

Rules for detecting SIP lines
Choosing "Edit Rules" takes you to a dialog box that allows you to specify whether SIP lines should be detected by the ECSTA via a set of rules, filtered out and thus not forwarded to the TAPI’s line management (See Set of Rules for Filtering Out SIP Lines).

Snapshot for active calls
The driver can validate existing calls. This prevents that calls are displayed on the PC that do no more exist in the PBX system.
Enter a time interval in seconds.
The higher this value the longer it takes for the driver to detect a hanging call. The lower this value the higher is the load on the PBX.

Retry MonitorStart
In the event that the driver cannot start monitoring an extension because, for example, the extension has not been connected to the PBX, the driver will attempt to start monitoring at periodic intervals.
Enter a time interval in seconds.

Version 6.0